Cincon TR25D-02y11A02 ACb Adapter 12vdc 1.3A 5vdc 2A 5Pin Din 13 Cincon TR25D-02y11A02 ACb Adapter 12vdc 1.3A 5vdc 2A 5P

  • Model: Cincon TR25D-02y11A02 ACb Adap
  • 4519 Units in Stock

 Ask a Question 

$66.62

Buy More,Save more.Need a large quantity?email us for a special quote.
QuantityDiscount Price
3 - 9$63.28
10 - 19$60.62
20 - 49$57.96
50 - 149$55.96
150 + $47.70


Add to Cart:

Cincon TR25D-02y11A02 ACb Adapter 12vdc 1.3A 5vdc 2A 5Pin Din 13

Cincon TR25D-02y11A02 ACb Adapter 12vdc 1.3A 5vdc 2A 5Pin Din 13mm 100-240vac Power Supply 100-240v ~ 0.6A 47-63Hz 
cULus 99BJ E176177

Pin 1, 2, 4= GND (-ve)
Pin3 = 5vdc
Pin5 = 12vdc
Shield = NC ( also May be pin4 NC)

Cincon Electronics Co. Ltd TR25D 
PRODCO AC ADAPTER TR25D-02 100-240V IN 5V 12V OUT
TR25D 25W SWITCHING ADAPTOR DUAL OUTPUT
Universal Input: 90 ~ 264Vac
Continuous Short Circuit Protection
Meets EN55022 Class B, conducted

OUTPUT CHARACTERISTICS:
Holdup Time ............................................. 16mS typ. @ 115Vac
Short Circuit Protection ........................................... Continuous 
Over Voltage Protection ................................................. Option
Over Load Protection ...................................................... Option
MECHANICAL CHARACTERISTICS:
Dimensions ............................................5.20x 2.28 x 1.18 Inches
Weight ............................................................................0.77 Pounds
AC Inlet ....................................................................... IEC320/C14
ENVIRONMENTAL CHARACTERISTICS:
Operating Temperature ............................................... 0 ~ 40˚C
Storage Temperature ................................................ -20 ~ 85˚C
INPUT CHARACTERISTICS:
Voltage .............................................................. 90 ~ 264Vac
Frequency ............................................................. 47 to 63Hz
Inrush Current ..................................... 50A Max. @ 264Vac
Conducted EMI ..................................... CISPR/FCC Class B
Isolation ..................................... Input to output =4,242Vdc
Leakage Current ................................................1.5mA max
1. Peak output current (total output power must less than 32W) lasting less than one minute with duty factor less than 5%.
During peak loading, output voltage may exceed total regulation limits.
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to the output cable. Peak to peak and RMS metering equipment shall
have a 20 MHz response with probes and cables maintaining frequency response from 200Hz to 100MHz bandwidth. Output ripple and spikes
are measured directly at the output terminals of the power supply without the use of the probe ground clip.
3. Total regulation is defined as the static output regulation at 25˚C, including initial tolerance, line voltage within stated limits. and load currents 
within stated limits. When V1 exceed rated load, the total regulation will be 10%.


All orders ship to worldwide.

Your IP Address is: 18.219.207.115
Copyright © 2024 Power Adapter Co. Powered by Power Adapter Company LTD