HITRON HSU100-13 24 VDC 2A Switching Regulated POWER SUPPLY NEW
Condition : New
Content : One Power Supply only Nothing else.
Description: HSU100-13 - AC-DC 19" COMPATIBLE EUROCARD MULTI-OUTPUT 100 WATTS SWITCHING MODE POWER SUPPLY
FEATURES:
19" COMPATIBLE EUROCARD FORMAT
MEET THE SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
HSU100 3UX10HPX160MM VMEbus STANDARD
Type : Switching Regulated Rackmount POWER SUPPLY
Manufacturer: HITRON ELECTRONICS CORPORTION
Model: HSU100-13
Description: SINGLE OUTPUT INDUSTRIAL PWR SUPPLY
INPUT : 115V
Manufacturer's INPUT SPECIFICATION
Input Voltage: 115Vac/230Vac dual selectable.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 25A @230Vac.
Input Current: HSU45 0.88A@115Vac/0.44A@230Vac.
Use T2.0A/250Vac fuse.
HSU60 1.2A@115Vac/0.7A@230Vac.
Use T2.5A/250Vac fuse.
HSU100 2.2A@115Vac/1.2A@230Vac.
Use T3.15A/250Vac fuse.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Power Fail Signal: Installed.
Remote (Logic) Inhibit: Available.
Hold-up Time: Typ. 20mS @115Vac/50mS @230Vac.
Earth leakage: Typ. 0.3mA @230Vac.
OUTPUT : 24V DC 2A
Manufacturer's OUTPUT SPECIFICATION
Output Wattage: Typ. 100 Watts for HSU100.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.4%.
Load Regulation: Main VO1 typ. 1.0%.
Aux. VO2 typ. 2-3.0% (PR).
2.0% (Mag. Amp.)
Aux. VO3 typ. 2-3.0% (PR).
Aux. VO4 typ. 2-3.0% (PR).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1 (latch).
Adjustability: Available at main output VO1 and
Aux. output VO2 (Mag. Amp.).
Remote Sense: Installed in main VO1.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
Manufacturer's GENERAL SPECIFICATION
Efficiency: Typ. 70-75%.
Switching Frequency: Typ. 100K Hz.
Circuit Topology: Forward circuit.
Transient Response: Typ. 3mS following a 25% load-change.
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
Power Density: 1.9 Watts / Cubic Inch for HSU100.
Operating Temperature: 0 to 50C at full load.
Derates linearly to 70C at half load.
Storage Temperature: -20 to 85C.
Temperature Coefficient: Typ. 0.04%/C.
Cooling: Free air convection cooling.
Construction format: 6,8,10HP(TE) X 3U X 160mm
19 compatible Eurocard VMEbus standard.
WEIGHT: HSU100 943.0g (33.26 Oz.)